Electromechanical Locks are integral components of modern video intercom systems, providing robust security and seamless access control for both residential and commercial properties. Properly connecting these locks to your video intercom ensures reliable operation and enhances the overall security of your premises. This guide explores the various connection schemes for electromechanical locks, including setups with and without a separate power supply, installation considerations for homes and apartments, and practical tips to help you achieve a secure and efficient intercom system setup. Connection Schemes for Electromechanical Locks Connecting an Electromechanical Lock (EML) to a video intercom system can be accomplished through different methods. The two primary schemes are: Using a Power Supply Block Using a Control Unit (BUZ) Without a Power Supply Block 1. Connection Scheme Using a Power Supply Block Overview: When connecting an electromechanical lock with a power supply block, the system relies on an external power source to handle the significant current required for unlocking. This method is straightforward and ensures that the lock receives the necessary power without overloading the intercom panel. Steps: Select a Suitable Power Supply: Voltage Requirements: Typically 12V or 24V DC, depending on the lock specifications. Current Capacity: Ensure the power supply can handle the lock’s current draw (usually several amperes). Wiring the Lock: Power Lines: Use high-gauge cables (0.75mm² to 1.5mm²) to connect the power supply block to the electromechanical lock, minimizing voltage drop over long distances. Control Lines: Connect the intercom panel’s relay to the lock, ensuring the relay can handle the lock’s current. Relay Configuration: Normally Open Contacts: The intercom panel should have relay contacts that close to send a brief electrical pulse to unlock the door. Ensure Compatibility: Verify that the intercom’s relay is rated for the lock’s current requirements. Integration with Access Control: Optional Controllers: If using electronic keys (e.g., Touch Memory or Proximity cards), integrate a controller that manages the access codes and interacts with the intercom system. Testing: Verify Operation: Press the intercom’s unlock button and ensure the lock responds with a smooth, brief unlocking pulse. Check for Overheating: Ensure the lock does not overheat during operation, indicating proper power handling. Considerations: Cable Length: For long runs (e.g., from the power supply to a gate), use cables with larger cross-sectional areas to prevent voltage drops. Relay Rating: Confirm that the intercom panel’s relay can handle the current drawn by the electromechanical lock. 2.

For related product selection, see [Access Control Systems](https://safsale.com/access-control-systems).

A relevant Safsale product example is [ACS-007 Access Control Solution](https://safsale.com/standard-solution-acs-007).

![ACS-007 Access Control Solution](https://safsale.com/image/catalog/seo-products/1642991872/standard-solution-acs-007.jpg)

For an adjacent option, see [Access Controllers and Readers](https://safsale.com/access-controllers-and-readers).

---

**Original technical guide:** [Safsale Smart Link Academy](https://safsale.com/smart-link-academy/connecting-electromechanical-locks-video-intercom)

**Safsale:** [safsale.com](https://safsale.com)


---

## Summary
Electromechanical locks are integrated into video intercom systems using either an external power supply block or a control unit to manage the electrical current required for unlocking. Proper installation requires selecting compatible power sources and using appropriate cable gauges to ensure reliable operation and prevent voltage drops.

## Themes
- Electromechanical lock installation
- Intercom system integration
- Power supply configurations
- Access control wiring

## Key takeaways
- Electromechanical locks require external power sources to handle the high current needed for unlocking operations.
- Wiring for locks should utilize 0.75mm to 1.5mm gauge cables to ensure efficient power delivery.
- Intercom panels typically use normally open relay contacts to trigger the unlocking pulse.
- Access control systems can be integrated with intercoms to manage electronic keys like proximity cards or touch memory.

## Insights
- The use of high gauge cabling is critical to prevent voltage drops over long distances between the power supply and the lock.
- Intercom relay capacity must be explicitly verified against the lock current draw to prevent hardware failure.
- The document implies that direct connection without a power supply is a viable but distinct method from the power supply block approach.

## Open questions / gaps
- What are the specific wiring steps for the control unit (BUZ) method mentioned in the overview?
- What are the technical limitations or risks of connecting an electromechanical lock without a separate power supply block?